Add to Cart
224S 716.8V 160A High Voltage Smart BMS Lifepo4 BMS 16S BMU in series battery management system energy storage UPS
716.8V160A HV BMS Configuration:
HV 224S716.8V 160A BMS solutions includes:
1set Master BMS, Model#: RBMS07-D20-160A716.8V
14sets 16S Slave BMU Model#: BMU08-16S8T12F
14sets 16S Wire Harness
Wire harness includes:
Voltage&Temperature acquisition wire,
BMU External Communication Wire with Shenji Port,
The power wire for the Fan.
GCE HV Master BMS and Accessories:
![]() | ![]() |
![]() | ![]() |
![]() | ![]() | ![]() |
12S-24S BMU(Slave) 12S-24S BMU has 8pcs of temperature sensors, Fan voltage 48V(17S-24S 12V), voltage detection range 0-5V,12V power supply, consumption less 20mA, CAN2.0 B communication | Wire harness-Signal acquisition wire18 P+20P wire, standard length 600mm,900mm,1200mm temperature sensor wire: standard length: 600mm,900mm,1200mm Fan Power wire: 600mm | Wire harness- communication wireCommunication wire is connecting from the master BMS to each BMU with a cascade connection, the last port is for terminal resistance
|
HV BMS Product Characteristics:
※ Advanced battery management system---The highly integrated battery management system can realize seamless monitoring.
※ Perfect self-checking and running status checking function, with HMI display screen, system running information is clear at a glance.
※ Complete and reliable system control and protection strategies, comprehensively guarantee battery safety and escort to extend the life of battery packs.
※ Modular design, configurable and expandable---multiple energy storage units can be flexibly combined and expanded into a larger energy storage system.
HV BMS Technical Parameters:
RBMS(master BMS) | 4U-125A/160A/250A |
protecting method | MCCB+Contactor |
Rated Current range | -250A~250A |
Voltage range | 384V-1000V |
Current sampling accuracy | 1.0%FSR |
Communication interface with PCS | RS485/CAN |
Communication interface with BMU | CAN |
Communication interface with GBMS | RS485/CAN |
Communication with monitoring software/EMS | Ethernet |
Support IAP upgrade | Yes |
Support HMI display and parameter settings | No(OptionalPlug in) |
Insulation detection | Yes(Optional) |
High voltage power module | Support DC start (optional) |
Dry contact output (normally open) | None |
Maximum qty of BMUs | 18 |
Power | 24VDC(18~28V) |
Power consumption | ≤25W |
Size (W*H*D)mm | 4U(440*178*500) |
Connection Way out | Back and front |
Tap center | support(optional) |
net weight | 23kg |
GCE HV 3-Level BMS Diagram Structure:
HV BMS Applications:
![]() | ![]() |
![]() | ![]() |
FAQs about GCE HV BMS:
Contact Information:
Bruce Liu
Marketing Director
bruceliu@hngce.com
0086-0136-2009-7954