GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Ask Latest Price
Video Channel
Brand Name :GCE
Model Number :2U
Certification :CE
Place of Origin :China
MOQ :2
Price :negotiate with:wenglin@hngce.com, WhatsAPP me: +86-15570747076
Payment Terms :T/T, L/C
Supply Ability :2000 Sets per Month
Delivery Time :20 work days
Packaging Details :Corrugated Carton, bundles, pallets, wooden box
Strings :64S
Battery Type :LFP/NMC/LTO
Max. voltage :350V, 500V(according to the rated voltage)
Max. current :50A
Voltage Range :0V-96V
Current sampling accuracy :1%FSR
Insulation withstand voltage :2800VDC <1mA 1min
Size(W*H*D)mm :2U (440*88*500)
Application :BESS UPS Solar Energy Storage Systems
more
Contact Now

Add to Cart

Find Similar Videos
High Voltage Battery Management System with IP20 Protection 2 Dry Contact Outputs 125A Max Current 00:45
High Voltage Battery Management System with IP20 Protection 2 Dry Contact Outputs 125A Max Current
GCE Integrated 60S 192V 100A High Voltage BMS Battery Management System Smart BMS For UPS BESS 01:01
GCE Integrated 60S 192V 100A High Voltage BMS Battery Management System Smart BMS For UPS BESS
Integrated BMS Battery Management System 75S 100A 240V For LifePO4 Battery Pack 01:16
Integrated BMS Battery Management System 75S 100A 240V For LifePO4 Battery Pack
Max Current 125A High Voltage BMS For 11 X 15S Battery Strings 00:43
Max Current 125A High Voltage BMS For 11 X 15S Battery Strings
High Voltage BMS , Smart lifepo4 BMS Lithium-ion battery management system for Industrial Battery Solution ESS UPS BESS 00:36
High Voltage BMS , Smart lifepo4 BMS Lithium-ion battery management system for Industrial Battery Solution ESS UPS BESS
50A 75S BMS 240V BMS Battery Energy Storage System With Overcharge Protection Master And Slave All In One Relay Bms 01:54
50A 75S BMS 240V BMS Battery Energy Storage System With Overcharge Protection Master And Slave All In One Relay Bms
Solar Energy Storage BMS 240V 50A Lithium Battery BMS Match With Deye Goodwe Sofar Inverters 10KW 20kWh Ups Application 00:42
Solar Energy Storage BMS 240V 50A Lithium Battery BMS Match With Deye Goodwe Sofar Inverters 10KW 20kWh Ups Application
75S 100A Master Slave BMS lithium battery management system 240V BMS for lifepo4 battery pack UPS BESS 01:57
75S 100A Master Slave BMS lithium battery management system 240V BMS for lifepo4 battery pack UPS BESS
GCE 168S 621.6V 100A Battery Monitoring System NMC Bms With External Display For Solar Battery Energy Storage And Ups 00:35
GCE 168S 621.6V 100A Battery Monitoring System NMC Bms With External Display For Solar Battery Energy Storage And Ups
View Product Description

GCE RS485 CAN Protocol ESS BMS 204.8V50A 64S High Voltage 2U BMS

Product Features:

※ Advanced battery management system---The highly integrated battery management system can realize seamless monitoring.

※ Perfect self-checking and running status checking function, with HMI display screen, system running information is clear at a glance.

※ Complete and reliable system control and protection strategies, comprehensively guarantee battery safety and escort to extend the life of battery packs.

※ Modular design, configurable and expandable---multiple energy storage units can be flexibly combined and expanded into a larger energy storage system.

※ Abundant communication interfaces---multiple RS485, CAN, Ethernet, dry contact input and output interfaces, supporting communication with most PCS and monitoring servers on the market.

※ The communication interface protocol is flexible---the factory comes with the company's communication protocol, and it can also be adapted to the PCS of different manufacturers according to customer needs.

※ The built-in large-capacity memory chip can store a large amount of key operating data, and an SD card can be added to realize battery historical data storage

※ Automatic circulation control and automatic parallel/offline control can easily realize the parallel connection of battery packs.

GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Application:

◎ Photovoltaic power station energy storage

◎ Island off-grid energy storage

◎ ESS

◎ Micro-grid

◎ UPS power supply

◎ Power System 220V DC power supply

GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Product Specifications:

GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Basic Parameters

Max. current 50A

Max. voltage

350V, 500V(according to the rated voltage)

Power consumption

≤15W

Current sampling accuracy

1%FSR

Insulation withstand voltage

2800VDC <1mA 1min

Protection level

IP20

Size(W*H*D)

482*89*500(mm)

New Weight

~10Kg

Communication Interface

Communication port with BMU

CAN

Communication port with UPS

RS485/CAN

Communication port with SBMS

RS485/CAN

Communication with monitoring software

Ethernet

Basic Function

Battery charge & discharge management

Available

Battery temperature management

Available

IAP Upgrade

Available

System protection parameter setting

Available

Short circuit protection

Available(6KA 20ms)

Pre-charge function

Available

Parallel circulation control

Available

Event record

Available(5000)

DC start

Available(Battery powered, Mains supply is only for the signal to start on and off the BMS)

Optional function

Insulation detection

No

HMI display

3.5 inches(Embedded in the chassis)

Stand-alone or parallel function

Set up before leaving the factory

Dry contact

Maximum 2 dry contact outputs

Others

Color

RAL9005 black sand grain

Installation method

Suitable for standard 19-inch rack installation

Incoming and outgoing wire method

Front side in and front side out.

Operating ambient temperature

-20℃~60℃

Operating ambient humidity

5%~75%RH

Comply with National standards

GB/T 16935.1 GB/T 17626.2 GB/T 17626.5

Certification

Comply with CE certification standards

RBMS Accessories List:

Name

Specifications

QTY

Image

Power Terminal

GPS50AFP Blue

1

GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Power Termina

GPS50AFP Red

1 GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Power terminal connector

S1339G2

4 GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

AC socket(writeable)

250V 10A

1 GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Dry contact terminal

5.08-6Pin

1 GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Terminating resistor

120R

1 GCE RS485 CAN Protocol Solar Battery System ESS BMS 204.8V50A 64S High Voltage 2U BMS

Precautions For Use:

1)There is a high voltage inside the energy storage system. It is strictly forbidden to open the case for disassembly,

assembly and maintenance without the company or its authorized technicians, otherwise the electric shock will be released and the warranty rights will be lost.

2)It is strictly prohibited for any wire or connector in the BMS to overlap the positive and negative poles of the battery,

otherwise there may be a danger of short circuits and damage to the circuit board.

3)it is strictly prohibited to be close to the water source or fire source to avoid the fire of the battery due to a short circuit or overheating.

4)after the secondary protection is triggered, the circuit breaker is controlled by BMS. After disconnection, the system must be powered off to eliminate the fault,

and can be powered on and started again after an interval of at least 1 minute, otherwise, it may cause damage to the shunt coil of the circuit breaker because it is too late to emit heat.

5)If you need to cold start the UPS/PCS from the battery, you must first close the battery switch on the UPS/PCS side before starting the battery.

If you start the battery first, and then close the battery switch on the UPS/PCS side, since the DC side of the UPS/PCS side generally has a large capacitance,

the instantaneous capacitance is equivalent to a short circuit. At this time, the current charged by the battery to the capacitor will be much higher than that of the RBMS machine.

The rated value of the contactor is very easy to cause ablation and adhesion of the contactor's contact.

The contact resistance of the contactor's contact increases and heats up or the contact cannot be disconnected, which triggers the secondary protection

Safety Precautions:

1)The tools used by installation and commissioning personnel must have insulation protection.

2)During installation, debugging and maintenance, you must wear insulated rubber gloves, goggles, and insulated rubber boots as appropriate to avoid safety accidents as much as possible.

3)If the metal of the wire ends during the installation, debugging and maintenance process falls into the battery room, be sure to use an insulated tool to take it out, and do not leave the sundries.

4)When maintenance is required, the main circuit breaker of the RBMS must be disconnected, and the connection between the battery pack and the PCS DC bus must be cut off.

5)According to different project requirements, the parameters such as the charge and discharge current and charge and discharge voltage of the battery management system have been set during the initial installation and commissioning.

The parameters must not be changed without authorization, otherwise, the battery life may be shortened, and the battery may be affected more seriously. Cause serious harm and cause safety accidents.

6)In case of fire around the energy storage cabinet, please use a dry powder fire extinguisher or fire sand to extinguish the fire. Using liquid to extinguish the fire may cause electric shock.

7)If the system is not used for a long time, be sure to disconnect the main circuit breaker of the battery cabinet.

8)Try to avoid long-term use in the following working environment:

◎Places that exceed the temperature or humidity range specified in the specification

◎Places subject to strong vibration or susceptible to impact

◎Places exposed to direct sunlight or close to heat sources

◎Places with dust, strong corrosive substances, flammable and explosive materials, and high salt spray

Inquiry Cart 0
You May Like
5U iron case Solar High Voltage BMS 384V 400A
5U iron case Solar High Voltage BMS 384V 400A
4U case overall High Voltage Battery Management System Bms 576V 250A
4U case overall High Voltage Battery Management System Bms 576V 250A
384V 250A 120S high voltage BMS for Lifepo4 Solar Battery System Cells Efficient
384V 250A 120S high voltage BMS for Lifepo4 Solar Battery System Cells Efficient
864V High Voltage Battery Management System
864V High Voltage Battery Management System
Ess Integrated BMS 32S 40S 45S 60S 64S 75S 100A 50A Ups BMS Lithium Battery
Ess Integrated BMS 32S 40S 45S 60S 64S 75S 100A 50A Ups BMS Lithium Battery
OEM Solar Battery System UPS 360V 384V 480V 50A 100A BMS LifePO4 With 48V 15S 16S BMU 120S For LTO NMC LFP Battery Pack
OEM Solar Battery System UPS 360V 384V 480V 50A 100A BMS LifePO4 With 48V 15S 16S BMU 120S For LTO NMC LFP Battery Pack
3U Solar BMS , Ems Energy Management System 480V DC 63A
3U Solar BMS , Ems Energy Management System 480V DC 63A
180S 576V 400A Modular Bms For BESS UPS Balancing Energy Storage 16S 15S
180S 576V 400A Modular Bms For BESS UPS Balancing Energy Storage 16S 15S
Battery Management Smart Bms System 180S 576V 125A 3U For PV Power Plant Storage
Battery Management Smart Bms System 180S 576V 125A 3U For PV Power Plant Storage
Lifepo4 High Voltage Bms With Relay Contactor 45S 144V 50A 2U
Lifepo4 High Voltage Bms With Relay Contactor 45S 144V 50A 2U
GCE 160S 512V 125A BMS For Off Grid Home Solar LFP Power Solution Battery Storage System UPS Lithium Ion Batteries
GCE 160S 512V 125A BMS For Off Grid Home Solar LFP Power Solution Battery Storage System UPS Lithium Ion Batteries
factory supply  High Voltage BMS 240S 768V 500A Lithium-ion battery solution bms with flexible protocal for ESS UPS BESS
factory supply High Voltage BMS 240S 768V 500A Lithium-ion battery solution bms with flexible protocal for ESS UPS BESS
GCE 176S 563.2V 125A Energy Storage BMS For Industrial And Commercial Energy Storage Ups Backup Power Supply
GCE 176S 563.2V 125A Energy Storage BMS For Industrial And Commercial Energy Storage Ups Backup Power Supply
Global leader BMS 160S bms 512V 100A lithium battery bms with CAN comunication for solar energy storage system
Global leader BMS 160S bms 512V 100A lithium battery bms with CAN comunication for solar energy storage system
GCE High Voltage BMS 255S 816V 400A Lithium-ion  Battery BMS for ESS UPS  Off grid Solar Energy Storage System
GCE High Voltage BMS 255S 816V 400A Lithium-ion Battery BMS for ESS UPS Off grid Solar Energy Storage System
Send your message to this supplier
*From:
*To:

Hunan GCE Technology Co.,Ltd

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now